6.6 KV class


avsAll dimensions are in mmTHE COPYRIGHT OF THESE DRAWINGS ANDOF ALL ANNEXES WHITCH ARE ENTRUSTEDTO A PERSON'S CARE ALWAYS REMAIN THEPROPERTY OF OUR FIRM. THEY MUST NOTBE COPIED OR DUPLICATED.NOT SHOWN TOOR PLACED AT THE DISPOSAL OF THIRDPERSONS WITHOUT OUR WRITTEN CONSENT.SCALEDRGCHDAPPDDATEDrawing No. Rev.REF.PROJECTIONREV. MODIFICATION DATE APPDMANUFACTURERSUNSHINE ENGINEERINGEmail :- sunshineengineering23@gmail.comMob. :- +91 749954423090 0.520 20861 0.5451M12 x 20mm Deep Min.36 0.3M6 x 10mm Deep Min. (2 Nos)M10 x 18mm Deep Min.ELECTRICAL SPECIFICATION IS:9431-19791) Rated Voltage...............................................................................6.6 kV.2) Dry Power Frequency Withstand Voltage Test (One Minute).......27 kV.3) Dry Lightning Impulse Withstand Voltage Test ............................60 kVpeak.4) Minimum Creepage Distance........................................................150 mm.MECHANICAL SPECIFICATION IS:9431-19791) Cantilever Failing Load F................................................................850 Kgs.2) Compression Failing Load .............................................................8000 Kgs.3) Tensile Failing Load .......................................................................1000 KgsOTHER :-1) Colour brick red.6.6kV Epoxy Insulator NTSUKNPitalePitale10/04/22 SE/EI06/001H-0005

EPOXY PROCESSING


STRENGTH

These materials have the specific characteristics needed forCreating high dielectric properties, mechanical strength as well as insulating properties for electrical applications. For over 50 years EPOXY and PUR have been the standard materials for achieving well engineered insulation characteristics in reference to heavy electrical usage

APPLICATIONS

EPOXY are used in a variety of applications in theMedium and high voltage industry. Besides the classical medium voltage from 12 to 36 kV and high voltage up 1000 kV other industries, like the automotive, high-speed train and motor stator applications show a rapid growth and acceptance in the market. The advantage lies in the fact that that in many cases, components can be built smaller, compared to conventional insulation technologies.